Related Experiment Video
Updated: Oct 12, 2026

Profiling the Triacylglyceride Contents in Bat Integumentary Lipids by Preparative Thin Layer Chromatography and MALDI-TOF Mass Spectrometry
Published on: September 5, 2013
Determination of polyoxyethyleneglycerol triricinoleate 35 (Cremophor EL) in plasma by pre-column derivatization and
A Sparreboom1, O van Tellingen, M T Huizing
1Department of Clinical Chemistry, Antoni van Leeuwenhoek Huis, The Netherlands Cancer Institute, Amsterdam, Netherlands.
Abstract:
A sensitive and selective reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of polyoxyethyleneglycerol triricinoleate 35 (Cremophor EL; CrEL), which requires only microvolumes (20 microliters) of plasma, has been developed and validated. The procedure is based on saponification of CrEL in alcoholic KOH, followed by extraction of the released fatty acid ricinoleic acid with chloroform and derivatization with 1-naphthylamine. Margaric acid was used as the internal standard. The products are separated using an HPLC system consisting of an analytical column packed with Spherisorb ODS-1 material and a mobile phase of methanol-acetonitrile-10 mM potassium phosphate buffer pH 7.0 (72:13:15, v/v). Detection was executed by UV absorption at 280 nm. The lower limit of quantitation and the lower limit of detection in plasma are 0.01 and 0.005% (v/v) of CrEL, respectively. The percentage deviation and precision of the procedure, over the validated concentration range of 0.01 to 1.0% (v/v) of CrEL in plasma, are < or = 8.0% and < or = 6.6%, respectively. Compared to the previously described bioassay, the presented HPLC method possesses superior sensitivity and reliability. Preliminary pharmacokinetic studies of CrEL in mice and patients receiving paclitaxel formulated in CrEL have demonstrated the applicability of the presented assay.
Related Concept Videos
Thin-Layer Chromatography (TLC): Overview
To begin the analysis, a mixture of compounds is spotted on the starting line on the TLC plate using a thin capillary. The bottom of the...
Principles Of Column Chromatography
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation

