Skull fracture caused by vacuum extraction

K Hickey1, P McKenna

  • 1Rotunda Hospital, Dublin, Ireland.

Obstetrics and Gynecology
|October 1, 1996
PubMed
Summary

Vacuum extractor use in assisted vaginal delivery may cause fetal skull fractures. While this infant recovered neurologically, the risk of fracture may be underestimated in routine practice.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A Cluster-Randomized Clinical Trial of Silver Diamine Fluoride vs Atraumatic Restoration in Older Adults.

Journal of dental research·2026
Same author

Input to the European strategy for particle physics: strong-field quantum electrodynamics.

European physical journal plus·2025
Same author

Obstetrical Events Support Team (OEST): Preventing harm, reducing costs from neonatal brain injury.

Irish medical journal·2025
Same author

Stable laser-acceleration of high-flux proton beams with plasma collimation.

Nature communications·2025
Same author

Adverse psychiatric effects of psychedelic drugs: a systematic review of case reports.

Psychological medicine·2024
Same author

Subtotal vaginal Hysterectomy.

Irish medical journal·2024

Area of Science:

  • Obstetrics and Gynecology
  • Neonatal Medicine
  • Pediatric Surgery

Background:

  • Assisted vaginal delivery increasingly utilizes vacuum extractors.
  • A common belief suggests vacuum cups detach before causing significant fetal harm.

Observation:

  • A term infant underwent rotational delivery using a vacuum extractor with a 6-cm metal cup applied paramedially for 12 minutes.
  • Vacuum pressure was 0.8 kg/cm2, with four traction efforts needed for delivery.
  • A subsequent neonatal skull X-ray revealed a comminuted parietal bone fracture at the cup site.

Findings:

  • The vacuum extractor can exert substantial traction force.
  • Fetal skull fractures, specifically parietal bone fractures, are a potential complication.
  • The actual incidence of vacuum extractor-related fractures may be higher than reported.

Implications:

  • Clinical vigilance is necessary during vacuum-assisted deliveries.
  • The potential for fetal skull fracture should be considered, even with seemingly normal outcomes.
  • Further research is warranted to determine the true incidence of neonatal fractures from vacuum extraction.