Related Experiment Video
Updated: Oct 7, 2026

Functional Magnetic Resonance Spectroscopy at 7 T in the Rat Barrel Cortex During Whisker Activation
Published on: February 8, 2019
Ultrafast perfusion-weighted MRI of functional brain activation in rats during forepaw stimulation: comparison with
C M Kerskens1, M Hoehn-Berlage, B Schmitz
1Max-Planck-Institute for Neurological Research, Cologne, Germany.
Abstract:
A fast version of the arterial spin tagging technique for the detection of cerebral perfusion is presented. Based on adiabatic spin inversion in combination with snapshot FLASH imaging, our technique allows the recording of perfusion changes with a temporal resolution of about 3 s. Differences of cerebral perfusion dependent on the choice of anesthesia were observed in rat brain. Furthermore, with this arterial spin tagging method we demonstrated perfusion increases in the somatosensory cortex of anaesthetized rats during forepaw stimulation. Comparison of the activated areas in the T2 -weighted BOLD images and the perfusion-weighted images showed good spatial correspondence, but the sensitivity to the functional activation was more than ten times higher in the perfusion technique.