Jove
Visualize
Contact Us

Related Experiment Videos

Laparoscopically guided peritoneal insertion in ventriculoperitoneal shunts

W Cuatico1, D Vannix

  • 1Neurosurgery Service, San Bernardino County Medical Center, California, USA.

Journal of Laparoendoscopic Surgery
|October 1, 1995
PubMed
Summary

Laparoscopic guidance for ventriculoperitoneal shunt insertion shows promise. This minimally invasive technique achieved zero insertion failures, outperforming traditional open methods in a small comparative study.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Hemolytic uremic syndrome in a child with burn injuries.

The Journal of burn care & rehabilitation·1998
Same author

A suggested design for tips of aneurysmal clips: a new concept.

Neurosurgery·1995
Same author

Spontaneous resolution of subdural hematomas.

Journal of neurosurgical sciences·1991
Same author

Further observations on spinal meningeal nerves and their role in pain production.

Acta neurochirurgica·1989
Same author

An anatomical and clinical investigation of spinal meningeal nerves.

Acta neurochirurgica·1988
Same author

Brain penetration and intracerebral haemorrhage following Jackson-Pratt drain insertion.

Acta neurochirurgica·1983
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Area of Science:

  • Neurosurgery
  • Minimally Invasive Surgery
  • Medical Device Technology

Background:

  • Ventriculoperitoneal shunts are critical for managing hydrocephalus.
  • Traditional open insertion of the peritoneal catheter can be challenging, with documented failure rates.
  • Obesity presents a specific challenge for open shunt insertion.

Purpose of the Study:

  • To describe and evaluate a novel technique for laparoscopic-guided insertion of the peritoneal end of ventriculoperitoneal shunts.
  • To compare the success rate of this laparoscopic technique against the standard open method.

Main Methods:

  • A series of 11 consecutive adult patients underwent laparoscopic-guided peritoneal end insertion of ventriculoperitoneal shunts.
  • A retrospective review of 11 prior cases using the standard open insertion technique was performed for comparison.

Related Experiment Videos

Main Results:

  • The laparoscopic-guided technique resulted in zero failures for peritoneal end insertion.
  • The standard open technique group experienced two insertion failures (18.2%).
  • One failure in the open group was due to subcutaneous placement in an obese patient.

Conclusions:

  • Laparoscopic-guided insertion of the peritoneal end of ventriculoperitoneal shunts is a safe and effective technique.
  • This method offers a potential advantage over open techniques, particularly in challenging cases.
  • The technique warrants consideration for adult ventriculoperitoneal shunt placement.