Discussion of the Z-value to use in calculating the F0-value for high-temperature sterilization processes
1University of Minnesota, Department of Food Science and Nutrition, Minneapolis 55455, USA.
Abstract:
The appropriate z-value to use in integrating heat process time-temperature data in the temperature range of 120.0-140.0 degrees C (248.0-284.0 degrees F) is discussed. We conclude that for control of Clostridium botulinum there is little risk in extrapolating a public health F0-value for C. botulinum to temperatures in the 132.0-138.0 degrees C (270.0-280.0 degrees F) range using a z-value of 10.0 degrees C (18.0 degrees F). It would seem prudent, at this time, when extrapolating data to conditions in the 132.0-138.0 degrees C (270.0-280.0 degrees F) range, that as a starting point an F0-value of 3.0 minutes be used as the minimum public health process. A design z-value of 10.0 degrees C (18.0 degrees F) is appropriate for Clostridium sporogenes to temperatures of 140.0 degrees C (284.0 degrees F). To control thermophilic microorganisms such as Bacillus stearothermophilus and Bacillus coagulans with processes at temperatures from 120.0-140.0 degrees C (248.0-284.0 degrees F), the effective z-value will be in the range of 7.0-8.0 degrees C (12.6-14.4 degrees F) instead of 10.0 degrees C (18.0 degrees F). This means that when we design and calculate processes at temperatures from 120.0-140.0 degrees C (248.0-284.0 degrees F), using a z-value of 10.0 degrees C (18.0 degrees F), the lethal effect against these organisms will be much larger than indicated by the F0-value of the process.
Related Concept Videos
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Physical Methods for Controlling Microbial Growth: Temperature
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Bioreactor Controls-II
Scale-Up Processes