Related Experiment Video
Updated: Aug 12, 2026

Cooling or Warming the Esophagus to Reduce Esophageal Injury During Left Atrial Ablation in the Treatment of Atrial Fibrillation
Published on: March 15, 2020
Temperature monitoring during radiofrequency ablation
J L Dinerman1, R D Berger, H Calkins
1Department of Medicine, Johns Hopkins Hospital, Baltimore, Maryland 21287-0409, USA.
Abstract:
Thermal injury is the primary mechanism of lesion formation during radiofrequency catheter ablation procedures. Irreversible tissue injury requires heating to approximately 50 degrees C. Temperatures above 100 degrees C result in coagulum formation. Because of this importance of temperature during radiofrequency catheter ablation procedures, temperature monitoring has been proposed as a tool to facilitate catheter ablation procedures. The results of recent clinical studies demonstrate that electrode temperatures do not differ at successful and failed ablation sites, electrode temperature does not predict or eliminate the possibility of arrhythmia recurrence, and closed-loop temperature control decreases but does not eliminate the development of coagulum nor guarantees that target temperatures will be achieved. These observations are due in large part to the important distinctions between electrode temperature, the temperature at the electrode-tissue interface, and the temperature at the ablation target. Nonetheless, temperature monitoring and temperature control are valuable tools during radiofrequency ablation procedures as they provide important information regarding the adequacy of tissue heating, minimize the development of coagulum, and maximize lesion size.
More Related Videos
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...

