Abstract:
Catheter guided ablation of cardiac arrhythmias is an effective and safe procedure for the treatment of most supraventricular and selected ventricular tachycardias. Because catheter manipulation is fluoroscopically guided, there is risk of radiation induced injury, especially during prolonged procedures. The Food and Drug Administration has recently issued a bulletin warning of the risks of acute skin injury occurring during fluoroscopically guided procedures that result in an exposure level exceeding 2 Gray units (Gy). This study was performed as an investigation into the risk of radiation induced skin injury during arrhythmia ablation procedures. The amount of radiation exposure for 500 patients who underwent ablation was calculated based upon fluoroscopy times and the entrance dose of radiation (0.02 Gy/min). The mean radiation exposure was 0.93 +/- 0.62 Gy. Although 5.6% of patients (n = 28) received enough radiation exposure to reach the threshold dose (2 Gy) for early transient erythema, no clinical manifestations of acute radiation induced skin injury were observed. No patients achieved the threshold dose for irreversible skin injury. Patients undergoing AV node ablation or modification received significantly less radiation (0.39 +/- 0.40 Gy and 0.79 +/- 0.44 Gy, respectively) than patients undergoing other ablation procedures (0.94-1.45 Gy, P < 0.05). There was no association between the magnitude of radiation exposure and the presence of underlying heart disease. Patients undergoing ablation of accessory pathways were exposed to more radiation if there was a right-sided pathway (1.69 +/- 0.93 Gy) compared to other sites (0.87-1.24 Gy, P < 0.05). This study demonstrates that the risk of significant radiation induced skin injury during arrhythmia ablation procedures is low provided that precautions are taken to minimize radiation exposure.
More Related Videos
06:25Cooling or Warming the Esophagus to Reduce Esophageal Injury During Left Atrial Ablation in the Treatment of Atrial Fibrillation
Published on: March 15, 2020
04:58Reduced Procedure Time and Variability with Active Esophageal Cooling During Radiofrequency Ablation for Atrial Fibrillation
Published on: August 25, 2022
Related Concept Videos
Mechanism of Cardiac Arrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Cardiac Catheterization I: Pre-Procedure Overview
Dysrhythmias V: Evaluating Dysrhythmias
Dysrhythmias VI: Management of Dysrhythmias