ELISA anti-HLA antibody screening identifies non-complement-fixing antibodies responsible for acute graft rejection.
A Nanni-Costa1, M P Scolari, S Iannelli
1Institute of Nephrology, St. Orsola University Hospital, Italy.
Abstract:
We report on a kidney transplant recipient experiencing an unexpected early acute vascular graft rejection. Retrospective analysis of patient serum samples, utilizing a new ELISA HLA screening technique, revealed that the rejection crisis and the subsequent graft loss were due to a pretransplant donor-specific pre-sensitization caused by a non-complement-fixing antibody of IgG2 class. The case illustrates the clinical significance of non-complement-fixing anti-HLA antibodies. In addition it is shown that ELISA methods are suitable for detecting potentially harmful donor pre-sensitization in waiting-list patients not detectable by standard lymphocytotoxicity techniques. Hence ELISA could be an alternative to flow cytometry for this purpose. It is concluded that screening and cross-matching techniques which detect non-complement-fixing anti-HLA antibodies could improve graft outcome, and should form part of the immunological monitoring of kidney transplant waiting-list patients.