Related Experiment Videos
Assessing neuroreceptor occupancy by continuous infusion of carbon-11 labeled radioligands
1Department of Nuclear Medicine, Chang Gung Memorial Hospital, 199 Tung Hwa North Road, Taipei, Taiwan, R.O.C.
European Journal of Nuclear Medicine
|February 1, 1996
Abstract:
In carbon-11 labeled radiotracer studies of neuroreceptors in the brain, a state of practical equilibrium, monitored with a simple dual-probe detector system, was achieved by injection of a bolus of tracer followed by a continuous infusion of the tracer. After investigating several different bolus-to-infusion activity ratios, we observed that a practical equilibrium state could be achieved with a slope of 0.02+/-0.001 cpsxkg/microCi/min for [11C]carfentanil studies in normal human beings. The usefulness of this approach to assess neuroreceptor occupancy was demonstrated in two cases.