Determination of vinylidene chloride in Saran films by electron capture gas-solid chromatography and confirmation by

Journal - Association of Official Analytical Chemists
|September 1, 1977
PubMed

Related Concept Videos

Chemical Ionization (CI) Mass Spectrometry01:21

Chemical Ionization (CI) Mass Spectrometry

The molecular ion peak of a molecule in the mass spectrum provides vital information for molecular identification. However, conventional electron impact ionization can lead to the rapid dissociation of some molecular ions before they reach the detector. A milder ionization method is required to increase the lifetime of such ionized analyte molecules. Chemical ionization (CI) is a gas-phase protonation reaction useful for mass-analyzing analyte molecules that are easily protonated to yield the...
Electrospray Ionization (ESI) Mass Spectrometry01:12

Electrospray Ionization (ESI) Mass Spectrometry

Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Cycloalkane Fragmentation01:05

Mass Spectrometry: Cycloalkane Fragmentation

In mass spectrometry, cycloalkanes exhibit distinct fragmentation patterns due to the inherent stability of their molecular ions compared to linear or branched alkanes. The ring structure of cycloalkanes provides additional stability to the molecular ions, often resulting in prominent ion peaks in the mass spectrum.
For example, cyclohexane molecular ions have a mass-to-charge ratio (m/z) of 84, which tends to produce a stronger signal than linear alkanes like hexane. This stability comes from...
Gas Chromatography–Mass Spectrometry (GC–MS)01:14

Gas Chromatography–Mass Spectrometry (GC–MS)

Gas chromatography–mass spectrometry (GC–MS) is the combination of analytical techniques of gas chromatography and mass spectrometry in a single instrument for analyzing a mixture of compounds. The gas chromatograph separates the compounds in the mixture, and the mass spectrometer analyzes each compound separately to determine the molecular masses and molecular structures.
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction01:13

Gas Chromatography: Introduction

Gas chromatography (GC) is a technique for separating and analyzing volatile compounds in a sample. Its primary purpose is to identify and quantify components in complex mixtures, making it essential in fields such as environmental analysis, pharmaceuticals, and petrochemicals. GC is also called vapor-phase chromatography (VPC) or gas-liquid partition chromatography (GLPC).
In GC,  a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Supercritical Fluid Chromatography01:18

Supercritical Fluid Chromatography

Supercritical fluid chromatography (SFC) provides a beneficial substitute for gas chromatography (GC) and liquid chromatography (LC) for certain samples because it merges the top attributes of both techniques. SFC allows the separation and analysis of compounds that GC or LC does not easily manage. These compounds are traditionally nonvolatile or thermally unstable, making GC unsuitable and lacking functional groups required for HPLC analysis.
SFC utilizes a supercritical fluid mobile phase,...