Related Experiment Videos
Myelography with Omnipaque (Iohexol) using basic radiographic facilities: the main adverse effects
B N Ndosi1, N K Ndosi, R R Kazema
1Department of Radiology, Muhimbili College of Health Sciences.
Summary
Myelography using Omnipaque 240 contrast medium is relatively safe, even with basic X-ray equipment, showing adverse effects similar to diagnostic lumbar puncture. Higher concentrations (180 and 300) also resulted in tolerable side effects.
Area of Science:
- Radiology and Imaging
- Neurology
- Patient Safety
Background:
- Myelography is a diagnostic imaging procedure used to visualize the spinal canal.
- Assessing adverse effects of contrast media is crucial for patient safety, especially in resource-limited settings.
- Omnipaque is a commonly used non-ionic, low-osmolar iodinated contrast medium.
Purpose of the Study:
- To document adverse effects of different Omnipaque concentrations during myelography.
- To evaluate the relationship between contrast concentration and adverse event severity.
- To inform optimal contrast selection for myelography under basic radiographic conditions.
Main Methods:
- Prospective, double-blind study comparing myelography with varying Omnipaque concentrations (180, 240, 300) to diagnostic lumbar puncture.
- 110 neurological patients undergoing myelography and 30 controls undergoing lumbar puncture were included.
- Adverse effects (headache, dizziness, nausea, vomiting, convulsions) were assessed and graded by a blinded neuro-physician.
Main Results:
- Overall adverse effects occurred in 63.6% of myelography cases versus 36.7% of controls (p < 0.05).
- Omnipaque concentrations of 180 and 300 were significantly associated with adverse effects (p = 0.017 and 0.016).
- Omnipaque 240 showed no significant difference in adverse effects compared to diagnostic lumbar puncture (p = 0.137).
Conclusions:
- Myelography with Omnipaque 240 is a relatively safe option, comparable to diagnostic lumbar puncture, even with limited radiographic facilities.
- The choice of Omnipaque 240 is recommended for myelography in sub-optimal radiographic settings.
- While higher concentrations (180 and 300) are associated with tolerable adverse effects, 240 offers a favorable safety profile.