Assessing ECG signal quality on a coronary care unit
Abstract:
Poor electrocardiograph (ECG) signal quality is associated with an increase in the number of false alarms, may degrade diagnostic information, and can increase the workload for coronary care unit (CCU) or other intensive care staff. It is important therefore to establish simple quantitative measures that can be used to demonstrate signal quality problems. In this study, a fixed-gain diagnostic bandwidth ECG from patients in a single CCU bed was monitored continuously for 10 weeks and measures which could relate to quality were calculated. These measures were the number of times the ECG exceeded a preset limit (out-of-range events, +/-4 mV) and the frequency content of the ECG plus superimposed noise in six different bandwidths (0.05-0.25, 0.25-10, 10-20, 20-48, 48-52, and 52-100 Hz). A computer-based data collection system calculated a 10 s average for each of the measures and logged these to memory. Following the data collection phase, good-quality baseline levels for the seven measures were calculated for each of the days studied and compared with levels during the evening-night (6 pm-6 am), which were in turn compared with levels during the day-time (6 am-6 pm). All measures were significantly lower (p < 0.001) for the selected good-quality ECGs compared with those recorded during the night, with low frequency, lower ECG bandwidth, and out-of-range events producing the greatest differences. Night-time noise levels were lower than day-time levels, and the largest reductions were found in the rate of out-of-range events (19.8 to 9.3 h-1) (p < 0.02), and low-frequency content less than 0.25 Hz (70 to 56 microV) (p < 0.01). Significant reductions during the night were also found in the lower ECG bandwidth 0.25-10 Hz (111 to 98 microV) (p < 0.01). No significant changes were found in the higher frequencies. We conclude that the low-frequency content and rate of out-of-range events are easy to obtain and could be used as measures for evaluating signal quality.
More Related Videos
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Acute Coronary Syndrome III: Diagnostic Studies
Dysrhythmias V: Evaluating Dysrhythmias