Colonoscopic miss rates of adenomas determined by back-to-back colonoscopies
D K Rex1, C S Cutler, G T Lemmel
1Department of Medicine, Indiana University School of Medicine, Indianapolis, USA.
Background & Aims:
The miss rate of colonoscopy for neoplasms is poorly understood. The aim of this study was to determine the miss rate of colonoscopy by same day back-to-back colonoscopy.
Methods:
Two consecutive same day colonoscopies were performed in 183 patients. The patients were randomized to undergo the second colonoscopy by the same or a different endoscopist and in the same or different position.
Results:
The overall miss rate for adenomas was 24%, 27% for adenomas < or = 5 mm, 13% for adenomas 6-9 mm, and 6% for adenomas > or = 1 cm. Patients with two or more adenomas at the first examination were more likely than patients with no or one adenoma detected at the first examination to have one or more adenomas at the second examination (odds ratio, 3.3; 95% confidence interval, 1.69-6.46). Right colon adenomas were missed more often (27%) than left colon adenomas (21%), but the difference was not significant. There was evidence of variation in sensitivity between endoscopists, but significant miss rates for small adenomas were found among essentially all endoscopists.
Conclusions:
Using current colonoscopic technology, there are significant miss rates for adenomas < 1 cm even with meticulous colonoscopy. Miss rates are low for adenomas > or = 1 cm. The results suggest the need for improvements in colonoscopic technology.
More Related Videos
04:09The Pocket-Creation Procedure of Endoscopic Submucosal Dissection for Large Rectal Laterally Spreading Tumors
Published on: February 13, 2026
06:46Caudal-to-cranial Approach in Laparoscopic Right Hemicolectomy with Complete Mesocolon Excision and D3 Lymph Node Dissection
Published on: January 9, 2026
Related Concept Videos
Assessment of the Rectum and Anus
Rectal Inspection
Begin by inspecting the perianal and anal areas for color, texture, rashes,...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...