The estimation of inspired desflurane concentration in a low-flow system
S Gowrie-Mohan1, V Muralitharan, G G Lockwood
1Department of Anaesthesia, Hammersmith Hospital, London.
Anaesthesia
|October 1, 1996
Summary
Predicting desflurane concentration during low-flow anesthesia is feasible. With a to-and-fro system, inspired desflurane levels stabilize quickly, allowing for predictable anesthetic delivery in ventilated adult patients.
Area of Science:
- Anesthesiology
- Respiratory Physiology
- Pharmacokinetics
Background:
- Low-flow anesthesia offers economic and environmental benefits.
- Accurate control of anesthetic gas concentration is crucial for patient safety.
- Desflurane is a commonly used volatile anesthetic agent.
Purpose of the Study:
- To evaluate the predictability of inspired desflurane concentration.
- To assess desflurane behavior in low-flow anesthesia using a to-and-fro breathing system.
- To determine the ratio of inspired desflurane concentration to vaporizer setting over time.
Main Methods:
- Adult patients undergoing mechanical ventilation were studied.
- A to-and-fro breathing system was utilized.
- Fresh gas flows of 1 L.min-1 and 2 L.min-1 were employed.
- Inspired desflurane concentration was measured against vaporizer settings.
Main Results:
- At 1 L.min-1 fresh gas flow, the inspired desflurane to vaporizer setting ratio reached approximately 0.75 after 9 minutes.
- At 2 L.min-1 fresh gas flow, this ratio approximated 0.9 after 2 minutes.
- These concentration ratios remained stable throughout the procedure, barring minor fluctuations after vaporizer adjustments.
Conclusions:
- Inspired desflurane concentration is predictable during low-flow anesthesia with a to-and-fro system.
- Rapid attainment of stable anesthetic concentrations is achievable with specific fresh gas flows.
- This predictability aids in precise anesthetic management during surgery.