The effect of helical CT on X-ray attenuation
Related Experiment Video
Updated: Oct 23, 2026

Microfocus X-ray CT (microCT) Imaging of Actinia equina (Cnidaria), Harmothoe sp. (Annelida), and Xenoturbella japonica (Xenacoelomorpha)
Published on: August 6, 2019
K D Hopper1, C A Gouldy, C J Kasales
1Department of Radiology, Pennsylvania State University, Hershey 17033, USA.
Purpose:
Conventional CT has been shown to have wide variability in measured CT attenuation, both temporally within the same scanner and between different scanners. Many radiologists have raised the concern that the increased noise and multiple variables associated with helical CT may lead to degradation in resolution, specifically causing errors in CT number values. This study was designed to specifically evaluate the performance of both types of CT scanning in this regard.
Method:
A Picker PQ2000 helical CT scanner was used to scan a phantom containing multiple tissue-equivalent densities, allowing the measurement of CT attenuation of soft tissue, distilled water, cortical bone, medullary bone, air, and fat with a variety of techniques. A Catphan phantom was imaged with a variety of slice thicknesses (2, 4, and 8 mm), phantom positions (isocenter, y = +20 cm), and pitches (1.0, 1.5, 2.0) using both conventional and helical sequences. The entire image set was repeated with two additional annuli placed around the Catphan phantom to simulate the abdomen and the calvarium. The attenuation measurements of the same imaging parameters for helical versus conventional CT were statistically compared.
Results:
No statistical differences were found for the CT numbers based on scan type (conventional versus helical) for all sequences and gantry positions tested, including helical CT with pitches > 1.0. Greater CT number variability was found with the extremes of tissue density such as with air and especially cortical bone, but were not statistically significant. The addition of the abdominal and calvarial annuli created a greater variation in CT attenuation values, but again were not statistically significant.
Conclusion:
The measurement of X-ray attenuation does not vary significantly with the use of the helical technique.
Related Concept Videos
X-ray Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography