Related Experiment Videos
Levonorgestrel concentrations during use of levonorgestrel rod (LNG ROD) implants
I Sivin1, P Lähteenmäki, S Ranta
1Center for Biomedical Research, Population Council, New York, NY 10021, USA.
Contraception
|February 1, 1997
Summary
This study found that levonorgestrel contraceptive implant effectiveness is not affected by body weight and determined the minimum effective drug concentration for pregnancy prevention. No pregnancies occurred in either group over three years.
Area of Science:
- Contraception
- Pharmacokinetics
- Reproductive Health
Background:
- Levonorgestrel (LNG) implants are a common form of long-acting reversible contraception.
- Understanding drug release profiles and factors influencing them is crucial for contraceptive efficacy.
- Norplant-2 implants represent an earlier formulation compared to newer two-rod systems.
Purpose of the Study:
- To compare levonorgestrel concentrations between a new two-rod implant system and Norplant-2 implants over three years.
- To investigate the relationship between levonorgestrel concentrations, time, body weight, and ponderal index.
- To establish the minimum levonorgestrel concentration required for effective contraception.
Main Methods:
- A three-year randomized trial involving 398 women.
- Blood samples collected at multiple time points (1, 3, 6, 9, 12 months, then semiannually).
- Assay of levonorgestrel concentrations and statistical analysis correlating with time, body weight, and implant type.
Main Results:
- Levonorgestrel concentrations decreased over time and with increasing body weight and ponderal index for both implant types.
- Higher levonorgestrel concentrations were observed in the third year for the new LNG ROD implants compared to Norplant-2.
- No pregnancies were reported in either group throughout the three-year study period.
Conclusions:
- The new LNG ROD implant system demonstrates sustained contraceptive efficacy over three years.
- The minimum effective levonorgestrel concentration for pregnancy prevention is likely below 200 pg/ml, possibly below 175 pg/ml.
- Body weight and ponderal index significantly influence levonorgestrel pharmacokinetics, but efficacy remains high.
Keywords:
Acceptors--womenComparative StudiesContraceptionContraceptive AgentsContraceptive Agents, FemaleContraceptive Agents, ProgestinContraceptive EffectivenessContraceptive ImplantsContraceptive MethodsDemographic FactorsExaminations And DiagnosesFamily PlanningFamily Planning ProgramsHematologic TestsLaboratory Examinations And DiagnosesLaboratory ProceduresLevonorgestrelPopulationPopulation DynamicsResearch MethodologyResearch ReportStudiesTime Factors