Related Experiment Video
Updated: Aug 15, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Myocardial technetium-99m-tetrofosmin and technetium-99m-sestamibi kinetics in normal subjects and patients with
G Münch1, J Neverve, I Matsunari
1Department of Nuclear Medicine, Technical University of Munich, Germany.
Unlabelled:
This study was designed to compare the tracer kinetics between 99mTc-sestamibi and 99mTc-tetrofosmin in a heterogeneous group of 24 patients admitted for routine perfusion imaging.
Methods:
Twelve patients were studied with 99mTc-tetrofosmin and 12 with 99mTc-sestamibi. In each group, six patients had a low likelihood for coronary artery disease, and six patients had angiographically proven coronary artery stenoses of > 75% or previous myocardial infarction. Analysis of myocardial and liver uptake and clearance as well as target-to-organ contrasts were performed with planar stress images.
Results:
Myocardial uptake of 99mTc-tetrofosmin was higher from 5 min (0.37 +/- 0.12 counts/pixel x MBq-1, p = 0.008) to 60 min (0.32 +/- 0.10 counts/pixel x MBq-1, p = 0.04) compared to 99mTc-sestamibi. Biological half-life for 99mTc-tetrofosmin (278 +/- 32 min) in normal myocardium was significantly shorter (p = 0.008) than for 99mTc-sestamibi (680 +/- 45 min). Biological liver half-life for 99mTc-tetrofosmin (67 +/- 16 min) was also significantly shorter (p = 0.02) than for 99mTc-sestamibi (136 +/- 18 min). Heart-to-lung ratios for 99mTc-tetrofosmin (2.49 +/- 0.43 at 5 min to 2.66 +/- 0.55 at 60 min) and 99mTc-sestamibi (2.52 +/- 0.37 at 5 min to 2.95 +/- 0.50 at 60 min) were similar. Whereas heart-to-liver ratios for 99mTc-tetrofosmin (1.04 +/- 0.24 at 5 min, increasing to 1.51 +/- 0.44 at 60 min) were significantly higher from 30-60 min postinjection (p = 0.05 at 30 min to p = 0.02 at 60 min) compared to the 99mTc-sestamibi (0.83 + 0.16 at 5 min to 1.08 +/- 0.27 at 60 min).
Conclusion:
Technetium-99m-tetrofosmin displays a shorter myocardial half-life compared to 99mTc-sestamibi. The rapid liver clearance of 99mTc-tetrofosmin, combined with comparable myocardial retention, resulted in higher heart-to-liver ratios but similar heart-to-lung contrasts compared to 99mTc-sestamibi from 30-60 min.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Blood Studies for Cardiovascular System I: Cardiac Biomarkers
The essential diagnostic tools for detecting myocardial necrosis and monitoring individuals suspected of having acute coronary syndrome (ACS) include:
Troponins
Troponins, particularly cardiac troponins I and T, are the most precise and sensitive markers of myocardial injury. They are detectable within 4-6 hours of myocardial injury and remain...
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System V: CT
Acute Coronary Syndrome III: Diagnostic Studies
Dysrhythmias V: Evaluating Dysrhythmias