Correspondence of closest gradient voxels--a robust registration algorithm

J L Ostuni1, R L Levin, J A Frank

  • 1Laboratory of Diagnostic Radiology Research, National Institutes of Health, Bethesda, MD 20892-1074, USA.

Journal of Magnetic Resonance Imaging : JMRI
|March 1, 1997
PubMed
Summary

A new automatic algorithm accurately registers medical images, even with missing data or large shifts. This intensity gradient-based method is reliable and easy to use for MRI volume registration.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Sexually dimorphic differences in angiogenesis markers predict brain aging trajectories.

bioRxiv : the preprint server for biology·2023
Same author

Correction to: P2X7R-dependent regulation of glycogen synthase kinase 3β and claudin-18 in alveolar epithelial type I cells of mice lung.

Histochemistry and cell biology·2018
Same author

Novel Syntrophic Populations Dominate an Ammonia-Tolerant Methanogenic Microbiome.

mSystems·2016
Same author

P2X7R-dependent regulation of glycogen synthase kinase 3β and claudin-18 in alveolar epithelial type I cells of mice lung.

Histochemistry and cell biology·2016
Same author

Improved metagenome assemblies and taxonomic binning using long-read circular consensus sequence data.

Scientific reports·2016
Same author

A red-shifted photochromic sulfonylurea for the remote control of pancreatic beta cell function.

Chemical communications (Cambridge, England)·2015

Area of Science:

  • Medical Imaging
  • Image Processing
  • Computational Anatomy

Background:

  • Accurate registration of medical imaging volumes is crucial for quantitative analysis and longitudinal studies.
  • Existing registration methods can struggle with variations in image intensity, significant patient movement, or incomplete data.

Purpose of the Study:

  • To present a robust, automatic volume registration algorithm based on intensity gradients.
  • To demonstrate the algorithm's effectiveness under challenging conditions, including unrelated voxel intensities, large displacements, and missing data.
  • To provide visualization tools for assessing registration convergence and identifying errors.

Main Methods:

  • Developed an automatic registration algorithm utilizing three-dimensional intensity gradients.

Related Experiment Videos

  • Employed a matching strategy based on iteratively finding correspondences between voxels with high gradient magnitudes.
  • Tested the algorithm on T2-weighted and proton-density Magnetic Resonance (MR) volumes with simulated rotations (up to 25 degrees) and translations (up to 25 mm).
  • Main Results:

    • Achieved highly accurate registrations with a mean error of less than one-fifth of a voxel.
    • Demonstrated robustness against unrelated inter-volume voxel intensities, significant object displacements, and substantial amounts of missing data.
    • Registration times were consistently under 30 minutes per volume pair.

    Conclusions:

    • The proposed intensity gradient-based algorithm provides a powerful and sequence-independent solution for MR volume registration.
    • The algorithm is user-friendly, offering clear visualization of registration convergence and error sources.
    • It offers a reliable method for medical image registration, even in the presence of data imperfections.