Related Experiment Videos
Validation of curve-fitting method for blood retention of 99mTc-GSA: comparison with blood sampling method
1Department of Radiology, Kansai Medical University, Osaka, Japan.
Abstract:
We investigated a curve-fitting method for the rate of blood retention of 99mTc-galactosyl serum albumin (GSA) as a substitute for the blood sampling method. Seven healthy volunteers and 27 patients with liver disease underwent 99mTc-GSA scanning. After normalization of the y-intercept as 100 percent, a biexponential regression curve for the precordial time-activity curve provided the percent injected dose (%ID) of 99mTc-GSA in the blood without blood sampling. The discrepancy between %ID obtained by the curve-fitting method and that by the multiple blood samples was minimal in normal volunteers 3.1 +/- 2.1% (mean+/-standard deviation, n = 77 sampling). Slightly greater discrepancy was observed in patients with liver disease (7.5 +/- 6.1%, n = 135 sampling). The %ID at 15 min after injection obtained from the fitted curve was significantly greater in patients with liver cirrhosis than in the controls (53.2 +/- 11.6%, n = 13; vs. 31.9 +/- 2.8%, n = 7, p < 0.0001). There was a highly linear correlation between the %IDs of 99mTc-GSA and the plasma retention rate for indocyanine green (r = -0.869, p < 0.0001, n = 27). These results indicate that the curve-fitting method provides an accurate %ID of 99mTc-GSA and could be a substitute for the blood sampling method.