Technetium-99m-labeled polydiethylenetriamine pentaacetic acid polymannosyl polylysine (DTPA-man-PL) was synthesized and tested for lymph node scintigraphy by subcutaneous administration. The agent was designed for receptor-mediated uptake by mannosebinding protein, which resides on the plasma membrane of reticuloendothelial cells.
Methods:
Subcutaneous injections of a 99mTc-labeled agent having 18 DTPA and 82 mannosyl groups attached to a polylysine of 100 units ([99mTc]DTPA18-man82-PL100) were made at the level of the metacarpus and metatarsus of three healthy rabbits. Images were acquired at 1, 6, 12 and 24 hr. Popliteal and axillary nodes were then assayed for percent of injected dose (%ID). A negative control study was performed in three normal rabbits with [99mTc]DTPA18-PL100.
Results:
Significant differences in mean 24-hr %ID between the receptor specific and nonspecific agents were observed for both the popliteal (p < 0.006) and axillary (p < 0.012) nodes. Popliteal percent injected dose at 24 hr was 3.00 +/- 0.72% for [99mTc]DTPA-man-PL and 0.13 +/- 0.08% for [99mTc] DTPA-polylysine. Axillary accumulation at 24 hr was 2.84 +/- 0.83% for [99mTc]DTPA-mannosyl-polylysine and 0.22 +/- 0.12% for [99mTc] DTPA-polylysine. Percent injected dose of the receptor-specific agent was highest (4%) during the 6-hr scan. Accumulation of the nonspecific agent by the popliteal and axillary nodes at 6-hr postinjection was approximately 0.5%.
Conclusion:
This study provides proof of principle for lymphoscintigraphy by receptor-mediated delivery of a nonparticulate imaging agent.
More Related Videos
09:34Dynamic Imaging of Chimeric Antigen Receptor T Cells with [18F]Tetrafluoroborate Positron Emission Tomography/Computed Tomography
Published on: February 17, 2022
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET