Related Experiment Videos
Effect of aluminium impurities in the generator-produced pertechnetate-99m ion on thyroid scintigrams
European Journal of Nuclear Medicine
|September 30, 1977
Abstract:
Cases of reduced uptake of pertechnetate-99m ion in the thyroid gland due to the presence, in the injected solution, of aluminum species at concentrations higher than 4 microgram/cm3 are reported. This inconvenience can be avoided either by injecting chromatographically pure pertechnetate-99m ion or by allowing the eluate of high aluminium content to stand for about 4 h.