Objectives:
Faster and less labor-intensive crossmatching procedures are needed, but they must be as safe as the traditional antiglobulin method. We present twelve years' experience with a procedure involving antibody screening, blood group checks, and computerized delivery control (ABCD test).
Methods:
We use a computer for validation and printing documents and declaring compatibility between patient and blood component, based on screening results and earlier-recorded data about the patient.
Results:
Of 257,400 units transfused during the period, 90% were declared compatible through the ABCD procedure, and 10% had to be crossmatched. We observed no hemolytic transfusion complications due to a failure of the procedure to detect red cell alloantibodies. Labor in the testing laboratory was reduced by 65% compared to a previous crossmatching period. Fewer blood units were returned unused.
Conclusion: