Related Experiment Video
Updated: Jul 30, 2026

Assembly and Operation of an Acoustofluidic Device for Enhanced Delivery of Molecular Compounds to Cells
Published on: January 21, 2021
Characteristics of transcranial Doppler signal enhancement using a phospholipid-containing echocontrast agent
M Kaps1, P Schaffer, K D Beller
1Department of Neurology, University at Lübeck, FRG.
Background And Purpose:
Ultrasound attenuation caused by the skull is a major limitation of transcranial Doppler. Echocontrast agents (EAs) may solve this problem. The aim of the present study was to investigate the characteristics of a new echocontrast agent (BY963) containing air bubbles stabilized by phospholipids.
Methods:
Nine healthy volunteers received three different doses (2.5, 5.0, and 10 mL) of BY963 at an injection rate of 0.25 mL/s. The Doppler signal amplitude obtained from the middle cerebral artery was recorded with a 2-MHz pulsed-wave Doppler system. After complete decay of the signal enhancement, upward stroking of the veins of the upper arm was performed to evaluate the stability of the EA in the venous system.
Results:
A dose-dependent increase of at least 30 dB in the Doppler signal amplitude lasted 19 to 47, 35 to 64, and 48 to 126 heart cycles (68% range) after 2.5, 5.0, and 10 mL EA, respectively. In 6 cases, there was a biphasic increase in EA enhancement. Upward stroking of the forearm, in general 12 to 18 minutes after administration, caused a Doppler signal enhancement of at least 30 dB in 6 cases.
Conclusions:
Each injection of BY963 caused a diagnostically relevant Doppler signal enhancement. A considerable amount of EA remained stable in the venous system for at least 12 minutes. The biphasic dose-response fits to models of dilution-indicator theory and indicates free recirculation, as well as a nonlinear washout curve.
Related Concept Videos
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...