Related Experiment Video
Updated: Aug 19, 2026

Using Deuterium Oxide as a Non-Invasive, Non-Lethal Tool for Assessing Body Composition and Water Consumption in Mammals
Published on: February 20, 2020
Water (H2O and D2O) molar absorptivity in the 1000-4000 cm-1 range and quantitative infrared spectroscopy of aqueous
Venyaminov SYu1, F G Prendergast
1Department of Pharmacology, Mayo Foundation, Rochester, Minnesota 55905, USA. venyaminov.sergei@mayo.edu
Abstract:
Water (H2O and D2O) molar absorptivity was measured by Fourier transform infrared transmission spectroscopy in the 1000-4000 cm-1 range at 25 degrees C. A series of assembled cells with path lengths from 1.2 to 120.5 microns was used for these measurements. The optimal path length (the path length of aqueous solution at which the IR spectrum of solute, corrected for water absorbance, has the highest signal-to-noise ratio) was calculated for all water absorbance bands. The results presented here show that the optimal path length does not depend on solute properties and is inversely proportional to the solvent (water) molar absorptivity. The maximal signal-to-noise ratio for measurements of IR spectra of aqueous solution in the 1650 cm-1 spectral region, of primary interest in biological applications, can be obtained at an optimal cell path lengths of 3-4 microns (H2O) and 40-60 microns (D2O). As an example, the signal-to-noise ratio was calculated as a function of the cell path length for the amide I (H2O) and amide I' (D2O) bands of an aqueous lysozyme solution. The molar absorptivities of water bands are several orders of magnitude weaker than those of the strongest bands of biological macromolecules in the same spectral regions. High net water absorbance in aqueous solutions is due simply to the very high molar concentration of water. A method is proposed for the quantitative measuring of the path length of the cell which exploits the molar absorptivity of the strongest water bands (stretching vibrations) or of bands which do not overlap with solute absorbance. A path length in the range from approximately 0.01 micron to approximately 1.0 mm can be determined with high precision using this technique for a samples of known concentration. Problems involved in the proper correction of strong water absorbance in IR spectra of aqueous solutions of biomolecules are discussed, including multiple reflections within the cell, the effects of pH, temperature, and perturbation of water spectral properties by polar solutes, as well as the selection of optimal spectral regions in which one may obtain the most precise absorbance corrections.
More Related Videos
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
07:38Characterization of Biological Absorption Spectra Spanning the Visible to the Short-Wave Infrared
Published on: January 10, 2025
Related Concept Videos
¹H NMR of Labile Protons: Deuterium (²H) Substitution
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
IR Spectrum Peak Broadening: Hydrogen Bonding
However, the extent of hydrogen bonding influences the observed stretching frequency and band broadening. Intermolecular or intramolecular hydrogen bonding...
IR and UV–Vis Spectroscopy of Carboxylic Acids
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency, 1710 cm−1. The C=O bond of the...
IR Frequency Region: X–H Stretching