Analysis of interval measurements on CSE multilead reference ECGs
Abstract:
As part of the International Electrotechnical Commission's (IEC) efforts to develop standards for interpretive electrocardiographs, electrocardiograms (ECGs) of the Common Standards of Electrocardiography (CSE) multilead measurement database were processed to (1) determine whether original ECG data would offer any advantage over cycle-repeated (artificial) ECGs and (2) compare the "clean" ECGs selected for interval measurement compliance testing (n = 100) with the remaining 25 "noisy" or nonsinus rhythm ECGs. Two sets of CSE measurement ECGs, namely, 125 original ECGs of the MO1 series and 125 artificial ECGs of the MA1 series were divided into 100 IEC-selected clean ECGs with good P and T waves and 25 noisy or nonsinus ECGs and processed for global wave duration and interval measurements (P duration, PR interval, QRS duration, and QT interval). The measured duration and interval values were compared against the CSE reference values (medians of referee values for 25 physician overread ECGs and medians of interpretive programs for the rest) to compute the measurement "differences". Also, the data of the median cardiac complex were evaluated for noise content. The original ECG data gave consistently smaller differences for all of the four measurements than the differences with the artificial ECG data. The noise levels in the median complexes formed from the original ECG data were significantly lower than the noise levels in the median complexes from the artificial ECG data. The noise levels in the medians of the 100 clean ECGs were lower than the noise levels in the medians of the 25 noisy ECGs for both the original and artificial ECG data.
Related Concept Videos
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage. When...
Dysrhythmias V: Evaluating Dysrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias