Related Experiment Video
Updated: Oct 3, 2026

Increasing Pulmonary Artery Pulsatile Flow Improves Hypoxic Pulmonary Hypertension in Piglets
Published on: May 11, 2015
Peak systolic velocity, resistance index and pulsatility index. Variations in measuring a pre-recorded videotape
R H Mikkonen1, J M Kreula, P J Virkkunen
1Department of Radiology, University Central Hospital, Helsinki, Finland.
Purpose:
To study variation in the process of measuring Doppler ultrasound (US) wave forms.
Material And Methods:
Eleven radiologists measured peak systolic velocity (PSV), resistance index (RI), and pulsatility index (PI) from a pre-recorded videotape. The wave forms were taken from the carotid, brachial, celiac, and renal interlobar arteries in a healthy volunteer. Each radiologist obtained measurements 10 times from a freely chosen wave form of 10 wave forms (10-beat series) and then a further set of measurements also 10 times from a specific wave form (1-beat series).
Results:
There was a significant variation in all the PSV, RI and PI values measured, both in the 1-beat series and in the 10-beat series. The greatest variation was seen in the PI values: up to 5.1-fold. Both intraobserver and interobserver reproducibilities were poor.
Conclusion:
The process of obtaining measurements from an identified wave form is a major source of error in Doppler US studies. Special attention should be paid to this final phase of an examination. We recommend that measurements be obtained from more than one heart beat.
More Related Videos
07:38Comprehensive Echocardiographic Assessment of Right Ventricle Function in a Rat Model of Pulmonary Arterial Hypertension
Published on: January 20, 2023
06:04Pulse-Wave Velocity, Flow-Mediated Dilation, and Carotid Intima-Media Thickness to Assess Cardiovascular Risk in Population with Metabolic Syndrome
Published on: September 27, 2024
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls between...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Vascular Resistance
The primary determinants of vascular resistance are vessel diameter, blood viscosity, and vessel length. Among these, vessel diameter plays the most significant role due to the fourth power relationship described by...
Measurement of Blood Pressure
Pulse