Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Experiment Videos

Apatite layer-coated titanium for use as bone bonding implants

W Q Yan1, T Nakamura, K Kawanabe

  • 1Department of Orthopaedic Surgery, Faculty of Medicine, Kyoto University, Japan.

Biomaterials
|September 1, 1997
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The use of a bioactive bone cement containing apatite-wollastonite glass-ceramic filler and bisphenol-a-glycidyl methacrylate resin for acetabular fixation in total hip arthroplasty: long-term follow-up results of a clinical trial.

The bone & joint journal·2019
Same author

Revision total hip arthroplasty using a Kerboull-type acetabular reinforcement device with bone allograft: minimum 4.5-year follow-up results and mechanical analysis.

The Journal of bone and joint surgery. British volume·2011
Same author

Bonding ability evaluation of bone cement on the cortical surface of rabbit's tibia.

Journal of materials science. Materials in medicine·2009
Same author

Clinical and radiological evaluation of revision hip arthroplasty using the cement-in-cement technique.

The Journal of bone and joint surgery. British volume·2008
Same author

Operative treatment of hip impingement caused by hypertrophy of the anterior inferior iliac spine.

The Journal of bone and joint surgery. British volume·2008
Same author

Revision total hip replacement using the Kerboull acetabular reinforcement device with morsellised or bulk graft: results at a mean follow-up of 8.7 years.

The Journal of bone and joint surgery. British volume·2007
Same journal

Corrigendum to "Photodynamic therapy produces enhanced efficacy of antitumor immunotherapy by simultaneously inducing intratumoral release of sorafenib" [Biomaterials 2020, 240, 119845].

Biomaterials·2026
Same journal

Mg-integrated octopus-inspired hydrogel dressing enables autonomous adhesion and wound closure for enhanced healing via sequential microenvironment regulation.

Biomaterials·2026
Same journal

Engineering miRNA-223 nanocomplexes via bioorthogonal self-assembly for precision therapy of intervertebral disc degeneration.

Biomaterials·2026
Same journal

Corrigendum to "Enhanced fluorescence imaging guided photodynamic therapy of sinoporphyrin sodium loaded graphene oxide" [Biomaterials 42 (2015) 16442].

Biomaterials·2026
Same journal

An injectable Ce-MnCo LDH nanozyme gel with cascade catalytic activity for acute radiation proctitis in rats.

Biomaterials·2026
Same journal

Peptide coacervate-mediated siRNA delivery for dual PD-1/PD-L1 blockade to enhance colorectal cancer immunotherapy.

Biomaterials·2026
See all related articles

A novel biomimetic apatite coating on titanium implants significantly enhances bone bonding and formation. This bioactive surface promotes direct bone apposition, improving implant integration and mechanical strength for better medical device performance.

Area of Science:

  • Biomaterials Science
  • Orthopedic Research
  • Surface Engineering

Background:

  • Titanium (Ti) implants are widely used in orthopedics but can suffer from suboptimal bone integration.
  • Developing bioactive coatings is crucial for enhancing the osseointegration of metallic implants.
  • Existing methods for coating titanium implants require further optimization for clinical success.

Purpose of the Study:

  • To develop and evaluate a new biomimetic method for creating thin, uniform apatite coatings on titanium implants in situ.
  • To assess the bone bonding and bone formation characteristics of apatite-coated titanium implants compared to uncoated controls.
  • To investigate the mechanical properties and histological outcomes of these biomimetic coatings after implantation.

Main Methods:

Related Experiment Videos

  • A biomimetic method involving apatite nucleation and growth in simulated body fluid (SBF) was used to coat titanium implants.
  • Coating characterization was performed using thin film X-ray diffraction and scanning electron microscopy-energy dispersive X-ray microanalysis (SEM-EPMA).
  • Bilateral implantation into rabbit tibiae followed by evaluation at 6, 10, and 25 weeks using mechanical detachment tests and undecalcified histology.
  • Main Results:

    • The biomimetic apatite coatings exhibited characteristics similar to natural bone.
    • Apatite-coated Ti implants showed significantly higher failure loads (P < 0.001) compared to uncoated controls at all time points.
    • Histological analysis revealed direct bone deposition onto the apatite coating without intervening soft tissue, unlike controls.

    Conclusions:

    • The in situ deposited apatite layer significantly enhances bone bonding strength by providing a bioactive surface.
    • This biomimetic coating facilitates early bone apposition, leading to improved osseointegration.
    • Apatite-coated titanium produced via this biomimetic process offers a promising solution for thin, strongly adhered bioactive coatings for medical implants.