Reduction of extremity dose in the radiopharmacy
Related Experiment Video
Updated: Oct 13, 2026

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
1Medical Physics Department, Raigmore Hospital, Inverness, UK.
Abstract:
With the future introduction of legislation originating from ICRP60 in mind, the operating procedures for the radiopharmacy were reviewed, with the intention of reducing extremity radiation dose. The radiopharmacist's index fingertip dose was measured using TLDs. The radiopharmacist received a mean dose of 0.7 mSv per 10 GBq of administered activity for the right (non-dominant hand) index finger and 0.2 mSv per 10 GBq for the left (dominant hand) index finger. These doses were comparable with other publications. The radiopharmacist received the largest part of the radiation dose during the preparation of 99Tc(m)-MDP. During this preparation, the saline was withdrawn into a syringe already containing 99Tc(m)-eluate, which results in a dose to the fingers. The technique was changed so that the saline and 99Tc(m)-eluate were withdrawn and injected separately into a MDP kit. This reduced the right finger radiation dose to 0.4 mSv per 10 GBq, while the left finger radiation dose remained at 0.2 mSv per 10 GBq. This shows that radiation doses can be effectively reduced using simple changes in procedure.
More Related Videos
11:38Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Drug Dosing: Geriatric Patients
Pharmacokinetics in Pediatric Patients: Drug Excretion
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Pharmaceutical Poisoning: Potential Scenarios