Related Experiment Video
Updated: Aug 10, 2026

Integration of Brain Tissue Saturation Monitoring in Cardiopulmonary Exercise Testing in Patients with Heart Failure
Published on: October 1, 2019
Esophageal pressure measurements in cardiopulmonary exercise testing
A M Thomas1, R E Turner, M F Tenholder
1University of Tennessee and Veterans Affairs Medical Center, Memphis 38163, USA.
Study Objectives:
We sought to determine the adaptability and effectiveness of a new esophageal balloon technique to measure changes in esophageal pressure (Pes) as a reflection of pleural pressure with progressive incremental exercise testing in normal subjects.
Design:
An 8F (0.9 cm) esophageal balloon catheter (Smart Cath; Allied Health Products; Riverside, Calif), a CP-100 pulmonary monitor (BiCore Monitoring Systems PC-100; Irvine, Calif), and a flow transducer (Var flex; Allied Health Products; Riverside, Calif) were connected to a breathing valve (model 2700; Hans-Rudolph Inc; Kansas City, Mo). This apparatus was then used to measure Pes during a graded cardiopulmonary exercise test (CPX) to symptom limitation.
Setting:
University-affiliated Veterans Affairs Hospital.
Participants:
Eight nonsmoking volunteers with normal results of pulmonary function tests.
Interventions:
Plots of deltaPes against pressure time product (PTP), minute ventilation (VE), and oxygen consumption (VO2) were obtained. Pes at baseline, anaerobic threshold (AT), and maximum oxygen consumption (VO2max) were obtained by comparing the Pes measurements from the computer printout to the corresponding breath-by-breath measurements on the CPX.
Measurements And Results:
The flow transducer (Varflex) connection added only 20 mL of dead space to the standard mouthpiece apparatus. The mean maximum work performance was 203+/-32 W. The mean VO2max was 29+/-9 mL/kg/min. The Pes at AT was 16+/-3 cm H2O. The Pes at maximal exercise was 42+/-16 cm H2O.
Conclusion:
The small esophageal balloon was well tolerated by all subjects. Plots of deltaPes vs PTP, VE, and VO2 demonstrated a linear correlation. This apparatus could be added to the standard CPX to assess the contribution of the diaphragm and respiratory muscles in patients with dyspnea.
More Related Videos
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Measurement of Blood Pressure
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes