In-vivo degradation of polyurethanes: transmission-FTIR microscopic characterization of polyurethanes sectioned by cryomicrotomy
Related Experiment Video
Updated: Oct 31, 2026

Stabilizing Hepatocellular Phenotype Using Optimized Synthetic Surfaces
Published on: September 26, 2014
S J McCarthy1, G F Meijs, N Mitchell
1CRC for Cardiac Technology, CSIRO Division of Chemicals and Polymers, Victoria, Australia.
Abstract:
A combination of cryomicrotomy and transmission Fourier transform infrared (FTIR) microscopy was used to investigate chemical changes in unstrained sheets of Pellethane 2363-80A, Tecoflex EG80A and Biomer caused by biodegradation (18 month subcutaneous ovine implant). Cryomicrotomy was used to obtain thin sections (ca. 2.5 microm) from the surface into the bulk, parallel to the plane of the surface. FTIR microscopy was then used to obtain infrared absorbance spectra in the range 4000-600 cm(-1). Comparisons between the infrared spectra (by spectral subtraction) from implant surface, implant interior and non-implanted controls were used to detect chemical changes. Scanning electron microscopy was used to assess microstructural changes owing to biodegradation. Biodegradation in Biomer was observed as uniform pitting and superficial fissuring (<2.0 microm depth) over the implant surface. Biodegradation in Pellethane 2363-80A and Tecoflex EG 80A was observed as severe localized embrittlement of the surface with fissures infiltrating up to 40 microm into the bulk. The chemical changes associated with biodegradation were observed as localized oxidation of the soft segment and hydrolysis of the urethane bonds joining hard and soft segments. Tecoflex EG80A was also found to be susceptible to localized hydrolysis of the urethane bond within the aliphatic hard segment. Biomer showed evidence of a significant non-specific degradation in the non-implanted wet control (37 degrees C phosphate buffered saline at pH 7.3) samples and in the implant bulk.
Related Concept Videos
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Types of Step-Growth Polymers: Polyesters
Polyesters are commonly prepared from terephthalic acid and ethylene glycol; the crude product is known as poly(ethylene terephthalate) or PET. However, polyesters are synthesized industrially by transesterification of dimethyl terephthalate with ethylene glycol at 150 °C. The two reactants and the polymer...
Classification and Mechanical Properties of Synthetic Polymers