Related Experiment Video
Updated: Aug 17, 2026

Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
Analysis of the Morgan-Elson chromogens by high-performance liquid chromatography
1Department of Biochemistry and Molecular Genetics, School of Medicine, University of Alabama at Birmingham 35294, USA.
Abstract:
The Morgan-Elson method for quantitative N-acetylhexosamine analysis is a two-step procedure comprising alkali treatment of the sugar and subsequent condensation of the resulting chromogens with p-dimethylaminobenzaldehyde (Ehrlich's reagent) to yield a colored product. In the present investigation, the products formed in the first step of the procedure were analyzed by high-performance liquid chromatography (HPLC) on a reversed-phase (C18) column, which was eluted with a water-methanol gradient; the absorbance of the effluent was monitored at 229 nm. The profile generated from alkali-treated N-acetylglucosamine exhibited two major peaks, in a ratio of approximately 2.5:1, which accounted for 94% of the total peak area. A third peak, accounting for 3% of the peak area, was eluted in an intermediate position, and several smaller peaks were also observed. The three predominant components, isolated by preparative HPLC, all gave a purple color on addition of Ehrlich's reagent, indicating that they were Morgan-Elson chromogens. The HPLC profile of alkali-treated N-acetylmannosamine was identical to that of the products generated from N-actylglucosamine, as was expected because of the elimination of the asymmetry at C-2 during formation of the chromogens. N-Acetylgalactosamine yielded two major peaks, which were eluted in the same positions as the two major products formed from N-acetylglucosamine, but the intermediate peak seen in the N-acetylglucosamine pattern was absent. The HPLC procedure allowed detection of as little as approximately 25 ng of N-acetylglucosamine and may therefore be of value as an alternative to the complete Morgan-Elson procedure when only small amounts of sample are available for quantitative analysis.
More Related Videos
07:51A Multi-Omics Extraction Method for the In-Depth Analysis of Synchronized Cultures of the Green Alga Chlamydomonas reinhardtii
Published on: August 8, 2019
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Types of Detectors
Ion-Exchange Chromatography
Electrophoresis: Overview
There...