Rebreathing in the Mapleson A, C and D breathing systems with sinusoidal and exponential flow waveforms
1Department of Anaesthesia, Royal Oldham Hospital, UK.
Abstract:
The degree of rebreathing in Mapleson A, C and D breathing systems for sinusoidal and exponential flow waveforms is analysed mathematically. The effects of altering the I:E ratio and of introducing an expiratory pause are investigated. The results for sinusoidal waveforms closely resemble those for a square wave. Exponential flow waveforms produce results similar to triangular flow waveforms. The Mapleson A system is always the most efficient. The Mapleson C system is efficient when the I:E ratio is 1:1, becoming less efficient with longer expiration and very inefficient with an expiratory pause. The Mapleson D system becomes efficient when the expiratory pause is long.
More Related Videos
08:26Quantitative Mapping of Specific Ventilation in the Human Lung using Proton Magnetic Resonance Imaging and Oxygen as a Contrast Agent
Published on: June 5, 2019
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Alterations in Respiration II
In Biot's breathing, the respiratory rate and depth are irregular, alternating between periods of deep gasping and apnea. Common causes include...
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration can...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Application of Integration: Problem Solving