Turbo spin-echo diffusion-weighted MR of ischemic stroke

K O Lövblad1, P M Jakob, Q Chen

  • 1Department of Radiology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Mass, USA.

AJNR. American Journal of Neuroradiology
|March 21, 1998
PubMed
Summary

This study evaluates a new magnetic resonance imaging technique called diffusion-weighted half-Fourier single-shot turbo spin-echo (HASTE) to identify acute stroke. Researchers compared this method against standard echo-planar imaging to see if it could reduce common image distortions near the skull base. The results show that HASTE is just as effective at detecting early brain damage while providing clearer images in areas where standard methods often fail. This approach allows hospitals without specialized echo-planar hardware to perform high-quality stroke scans using conventional 1.5 Tesla scanners.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Image space formalism of convolutional neural networks for k-space interpolation.

Magnetic resonance in medicine·2025
Same author

Agreement between early-phase amyloid-PET and pulsed arterial spin labeling in a memory clinic cohort.

Journal of molecular medicine (Berlin, Germany)·2025
Same author

Towards robust in vivo quantification of oscillating biomagnetic fields using Rotary Excitation based MRI.

Scientific reports·2022
Same author

T<sub>1</sub>-independent exchange rate quantification using saturation- or phase sensitive-water exchange spectroscopy.

Journal of magnetic resonance (San Diego, Calif. : 1997)·2022
Same author

Answer to Letter to the Editor: High-resolution Black Blood Vessel Wall Imaging in COVID-19 Encephalopathy-is it Really Endotheliitis?

Clinical neuroradiology·2021
Same author

Large Neck and Strong Ostium Inflow as the Potential Causes for Delayed Occlusion of Unruptured Sidewall Intracranial Aneurysms Treated by Flow Diverter.

AJNR. American journal of neuroradiology·2020

Area of Science:

  • Medical imaging diagnostics within neurology
  • Clinical applications of diffusion-weighted HASTE imaging

Background:

Standard magnetic resonance imaging for acute stroke often relies on echo-planar technology to capture rapid diffusion data. This approach frequently suffers from significant susceptibility artifacts when scanning regions near the skull base. Such distortions can obscure critical diagnostic information in the posterior fossa and temporal lobes. No prior work had resolved how to maintain diagnostic sensitivity while eliminating these specific technical limitations. That uncertainty drove the investigation into alternative pulse sequences for clinical stroke services. Researchers sought a method that avoids the reliance on specialized hardware while preserving image quality. This gap motivated the testing of a multisection technique capable of producing reliable diffusion maps. The current study addresses these challenges by comparing a novel spin-echo sequence against established protocols.

Purpose Of The Study:

The objective of this study was to determine if diffusion-weighted HASTE imaging can overcome limitations inherent in other diffusion-weighted techniques. Researchers specifically aimed to address the requirement for echo-planar technology in standard stroke protocols. They also sought to mitigate susceptibility artifacts that frequently degrade image quality near the skull base. The investigation focused on whether this multisection technique could provide equivalent diagnostic performance for acute ischemia. By testing this approach, the team hoped to expand the accessibility of diffusion imaging to conventional scanner systems. The study was motivated by the need for clearer visualization in anatomically complex regions like the posterior fossa. Investigators aimed to validate the sequence in a prospective cohort of patients presenting with acute neurologic dysfunction. This work ultimately explores whether HASTE offers a robust alternative for clinical stroke services.

Keywords:
Magnetic resonance imagingNeurologic dysfunctionPosterior fossaSusceptibility artifacts

Frequently Asked Questions

The researchers propose that HASTE sequences identify acute infarcts by displaying hyperintensities identical to those seen on echo-planar imaging. Unlike the latter, this technique avoids susceptibility-related distortions, allowing for more accurate lesion localization near the skull base.

The study utilizes a diffusion-weighted half-Fourier single-shot turbo spin-echo sequence. This specific pulse sequence allows for rapid image acquisition without requiring the specialized echo-planar hardware typically needed for diffusion-weighted scans.

The posterior fossa and inferior frontal or temporal lobes are necessary to evaluate because these regions are highly prone to susceptibility artifacts. Standard echo-planar imaging often fails here, whereas the HASTE sequence maintains clear visualization.

Related Experiment Videos

Main Methods:

The team conducted a prospective study involving forty subjects referred for acute neurologic dysfunction. Review approach involved comparing two distinct magnetic resonance sequences for each patient. Clinicians performed brain scans using both standard echo-planar and the newer turbo spin-echo protocols. Analysts evaluated every scan for the presence of hyperintensities that signify ischemic damage. They also scrutinized the images to identify any technical distortions or susceptibility-related artifacts. The researchers specifically looked for these issues in regions near the skull base. All participants were scanned within twenty-four hours of their initial symptoms. This design ensured that the diagnostic capabilities of both methods were assessed under identical clinical conditions.

Main Results:

Key findings from the literature demonstrate that the HASTE sequence detects early ischemia with accuracy equal to echo-planar imaging. The new method successfully identified all infarcts observed in the patient cohort. Researchers noted that the technique produced clear images without susceptibility artifacts in all stroke cases. In twelve patients without acute lesions, the sequence provided consistent diagnostic clarity. One specific instance occurred where a hyperintensity on echo-planar imaging proved to be a false artifact upon HASTE review. The study confirms that the sequence functions reliably on conventional 1.5 Tesla systems. These results highlight the ability to perform fast multiplanar imaging in regions previously prone to distortion. The data support the implementation of this sequence as a viable alternative for acute stroke protocols.

Conclusions:

The authors propose that the HASTE sequence provides equivalent diagnostic performance to echo-planar imaging for identifying early ischemia. Synthesis and implications suggest that this technique effectively eliminates common susceptibility distortions in challenging anatomical regions. The findings indicate that the method remains robust within the posterior fossa and inferior frontal lobes. Clinicians may utilize this approach to obtain clear multiplanar images without the need for specialized hardware. The researchers note that the sequence successfully distinguishes true infarcts from artifacts that occasionally appear on standard scans. This evidence supports the use of conventional 1.5 Tesla systems for acute stroke assessment in various clinical settings. The study concludes that the absence of significant image degradation enhances the reliability of stroke diagnosis. These results offer a practical alternative for facilities lacking advanced echo-planar capabilities.

The researchers used diffusion-weighted images to compare the diagnostic accuracy of HASTE against standard echo-planar sequences. These data types allowed for the direct observation of hyperintensities and the identification of false-positive artifacts.

The authors measured the presence of hyperintensities corresponding to infarcts and the occurrence of image distortions. They found that in one patient, a hyperintensity on echo-planar images was correctly identified as an artifact using the HASTE sequence.

The researchers propose that this technique permits fast multiplanar imaging on conventional 1.5 Tesla systems. This implication suggests that hospitals without advanced echo-planar capabilities can still perform reliable stroke evaluations.