Related Experiment Video
Updated: Aug 29, 2026

Electrophoretic Separation of Proteins
Published on: June 12, 2008
High-resolution density gradient electrophoresis of proteins and subcellular organelles
1Division of Cellular Biochemistry, The Netherlands Cancer Institute, Amsterdam. atulp@nki.nl
Abstract:
Following a concept developed by Bier et al. (Electrophoresis 1993, 14, 1011-1018), binary mixtures of amphoteric buffers with low conductivity and a good buffering capacity permit rapid rate zonal separation of proteins on a density gradient electrophoresis apparatus (7 cm, x 2.2 cm). At pH 8.66 and 250 V, beta-lactoglobulin (Mr 36600) was separated into the A and B isoforms within 44 min; human transferrin (Mr 76000-81000) was separated into its sialylated glycoforms and carbonic anhydrase (Mr 30000) separated into its isoenzymes. From these results we arrive at the term high-performance density gradient electrophoresis. Compartments belonging to the endosomal system were separated by density gradient electrophoresis. Early endosomes, recycling vesicles, intermediate endosomes, late endosomes and lysomes became well-separated after 80 min at 10 mA using [125I]transferrin and horseradish peroxidase as reporter molecules in pulse-chase regimes. Mixtures of Bier buffers and standard electrophoresis media permitted very short separation times (19 min at 10 mA) for the endosomal compartments. Concommittantly, endoplasmic reticulum and proteasomes were well resolved.
Related Concept Videos
Subcellular Fractionation
Differential Centrifugation
Differential centrifugation is...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Electrophoresis: Overview
There...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...