Related Experiment Video
Updated: Aug 19, 2026

Intra-Operative Neural Monitoring of Thyroid Surgery in a Porcine Model
Published on: February 11, 2019
Electrophysiologic nerve stimulation for identifying the recurrent laryngeal nerve in thyroid surgery: review of 70
1Department of Surgical Education, Memorial Medical Center, Savannah, Georgia, USA.
Abstract:
To describe a simple technique for identifying the recurrent laryngeal nerve (RLN) with a nerve stimulator to prevent damage to the nerve during thyroid surgery. A retrospective review of 70 thyroidectomies performed from October 1989 to January 1995 by one surgeon using electrophysiologic nerve stimulation to identify the RLN was conducted. The technique is described. Outpatient flexible fiberoptic laryngoscopy was performed preoperatively and postoperatively in all patients. From 70 thyroidectomies, 80 RLNs were identified to be at risk for injury. Five patients had transient unilateral vocal cord paresis postoperatively. No RLN transection or permanent vocal cord paralysis occurred. This is the first large series of patients undergoing the use of electrophysiologic nerve stimulation for identifying the RLN during thyroid surgery. We found the technique to be useful and safe for identifying the RLN. We present this technique as a less costly and time-consuming alternative to intraoperative RLN monitoring.