Bond strength of multi-step and simplified-step systems
A H Tjan1, J Castelnuovo, P Liu
1Department of Restorative Dentistry, Loma Linda University, School of Dentistry, California, USA.
American Journal of Dentistry
|December 1, 1996
Summary
OptiBond FL demonstrated superior bond strength compared to its multi-step counterpart, OptiBond. All-Bond 2 also showed higher shear bond strength than One-Step, indicating simplified-step systems can achieve strong dentin bonding.
Area of Science:
- Dental Materials Science
- Adhesive Dentistry
- Biomaterials Engineering
Background:
- Dentin bonding systems are crucial for the longevity of dental restorations.
- Comparing multi-step and simplified-step systems is essential for clinical decision-making.
- Understanding the in vitro shear bond strength (SBS) provides insights into material performance.
Purpose of the Study:
- To compare the in vitro shear bond strength (SBS) of three pairs of multi-step and simplified-step dentin bonding systems.
- Specifically evaluate OptiBond vs. OptiBond FL, All-Bond 2 vs. One-Step, and Tenure vs. Tenure Quik.
- Determine if simplified-step systems can match or exceed the performance of their multi-step counterparts.
Main Methods:
- 60 human mandibular molars were prepared to expose dentin surfaces.
- Dentin surfaces were treated with six different bonding systems (three pairs).
- Resin composite cylinders were bonded, followed by storage and thermocycling before shear testing.
Main Results:
- All-Bond 2 and OptiBond FL exhibited significantly higher shear bond strength than their respective simplified-step counterparts (p < 0.05).
- The Tenure/Tenure Quik pair did not show a statistically significant difference.
- OptiBond FL was the only simplified-step system that demonstrated improved bond strength.
Conclusions:
- Simplified-step dentin bonding systems, such as OptiBond FL and All-Bond 2, can achieve high in vitro shear bond strength.
- OptiBond FL represents an advancement in simplified-step dentin bonding technology.
- Further clinical studies are warranted to confirm these findings in vivo.