A physical analysis of the ion parametric resonance model

R K Adair1

  • 1Department of Physics, Yale University, New Haven, Connecticut 06516, USA. adair@nepmail.physics.yale.edu

Bioelectromagnetics
|April 29, 1998
PubMed
Summary

This study clarifies the ion parametric resonance model, showing weak magnetic fields cannot alter ion transition rates. The model fails to explain biological effects of extremely low frequency magnetic fields.

Related Concept Videos

Resonance and Hybrid Structures02:16

Resonance and Hybrid Structures

According to the theory of resonance, if two or more Lewis structures with the same arrangement of atoms can be written for a molecule, ion, or radical, the actual distribution of electrons is an average of that shown by the various Lewis structures.
Resonance Structures and Resonance Hybrids
The Lewis structure of a nitrite anion (NO2−) may actually be drawn in two different ways, distinguished by the locations of the N–O and N=O bonds.
Concept of Resonance and its Characteristics01:19

Concept of Resonance and its Characteristics

If a driven oscillator needs to resonate at a specific frequency, then very light damping is required. An example of light damping includes playing piano strings and many other musical instruments. Conversely, to achieve small-amplitude oscillations as in a car's suspension system, heavy damping is required. Heavy damping reduces the amplitude, but the tradeoff is that the system responds at more frequencies. Speed bumps and gravel roads prove that even a car's suspension system is not immune...
Mass Analyzers: Overview01:13

Mass Analyzers: Overview

The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
Mass Analyzers: Common Types01:19

Mass Analyzers: Common Types

The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
Double Resonance Techniques: Overview01:12

Double Resonance Techniques: Overview

Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Parallel Resonance01:23

Parallel Resonance

The parallel RLC circuit is an arrangement where the resistor (R), inductor (L), and capacitor (C) are all connected to the same nodes and, as a result, share the same voltage across them. The parallel RLC circuit is analyzed in terms of admittance (Y), which reflects the ease with which current can flow. The admittance is given by: