1Ophthalmology Department, First Affiliated Hospital, Jiangxi Medical College, Nanchan.
Objective:
To improve the socket reconstruction after enucleation.
Methods:
Hydroxyapatite (HA, made in China) was made into a porous HA sphere and wrapped up in the scleral shell as a mobile integrated orbital implant. It was applied to 43 patients with enucleation and anophthalmia, The surgical technique is described.
Results:
All sockets have been corrected very well and the prosthetic mobility and the cosmetic appearance are excellent. After a follow-up of 6 to 24 months, no migration or extrusion of the implant or infection occurred.
Conclusion: