Related Experiment Video
Updated: Aug 12, 2026

Performing Microscope-Mounted Y-Shaped Cutting Tests
Published on: January 20, 2023
Comparison of energy required for phaco-chop and divide and conquer phacoemulsification
P DeBry1, R J Olson, A S Crandall
1University of Utah Health Sciences Center, Salt Lake City, USA.
Purpose:
To evaluate the safety and usefulness of phaco-chop cataract extraction.
Setting:
A university-associated, multispecialty ophthalmology practice.
Methods:
Fifty-three patients in a university-associated ophthalmology practice had cataract extraction, 32 by the phaco-chop technique and 21 by four-quadrant divide and conquer phacoemulsification. Phacoemulsification energy and complication rates were compared.
Results:
Mean phacoemulsification energy was significantly lower in the phaco-chop group (mean 782 J +/- 446 [SD]) than in the divide and conquer group (mean 3264 +/- 1218 J)(P < .00001). No complications occurred in either group.
Conclusion:
The phaco-chop technique provided safe, effective cataract extraction with significantly less energy than that required for divide and conquer phacoemulsification.