[Pulse wave recording device]

L N Azargaev, V V Boronoev, V N Poplaukhin

    Meditsinskaia Tekhnika
    |June 5, 1998
    PubMed
    Summary

    This study introduces an improved pulse wave recording device that enhances accuracy and reduces diagnosis time. Pneumatic pressing offers superior reproducibility compared to mechanical methods for sphygmogram analysis.

    Related Concept Videos

    You might also read

    Related Articles

    Articles linked to this work by shared authors, journal, and citation graph.

    Sort by
    Same author

    [Pulse wave contour analysis in automated mode].

    Meditsinskaia tekhnika·2014
    Same author

    Measurements of atmospheric-turbulence-structure parameter using a space-limited laser beam.

    Optics letters·2009
    Same author

    [Differential sphygmogram of the radial artery in the evaluation of the heart pumping function].

    Fiziologiia cheloveka·2007
    Same author

    [Technical specificity of synchronous registration of pulse].

    Meditsinskaia tekhnika·2005
    Same author

    [Interrelations between time intervals of kinetocardiogram and pulsogram].

    Fiziologiia cheloveka·2004
    Same author

    [Amplitude-time and phase characteristics of pulse signal force transducer in multizone pulse diagnosis].

    Meditsinskaia tekhnika·1998

    Area of Science:

    • Biomedical Engineering
    • Physiology

    Background:

    • Sphygmogram recording accuracy is crucial for pulse wave analysis.
    • Existing mechanical pressing methods can lead to inaccuracies and reproducibility issues.

    Purpose of the Study:

    • To explain causes of incorrect sphygmogram recording.
    • To detail the design and technical features of a novel pulse wave recording device.
    • To demonstrate the advantages of pneumatic pressing for pulse wave analysis.

    Main Methods:

    • Described the physical principle of a pulse wave recording device.
    • Compared pneumatic pressing with mechanical pressing for accuracy and reproducibility.
    • Conducted trials to assess the time efficiency of the proposed device.

    Main Results:

    • Pneumatic pressing significantly enhances the reproducibility and accuracy of pulse wave recording.
    • The proposed device reduces the time required for pulse diagnosis.
    • Identified key factors contributing to incorrect sphygmogram recording.

    Conclusions:

    • The novel pulse wave recording device, utilizing pneumatic pressing, offers improved accuracy and efficiency.
    • This technology facilitates faster and more reliable pulse diagnosis.
    • Pneumatic pressing is advantageous over mechanical pressing for clinical applications.