Related Experiment Video
Updated: Aug 15, 2026

Catheter Ablation in Combination With Left Atrial Appendage Closure for Atrial Fibrillation
Published on: February 26, 2013
The transseptal approach for ablation of cardiac arrhythmias: experience of 104 procedures
1Manchester Heart Center, Royal Infirmary, UK.
Objective:
To report retrospectively on the training and subsequent experience of two operators in transseptal ablation of arrhythmias arising in the left atrium and left atrioventricular annulus, to show whether, with adequate training and careful attention to detail, this is a safe and effective technique.
Setting:
Electrophysiological studies and transseptal procedures were performed in the electrophysiology laboratories of the Moffatt Hospital, University of California at San Francisco (39) and Manchester Royal Infirmary (65) from January 1993 to June 1997. Close supervision by a fully trained operator was provided for at least the first 20 procedures performed by each operator.
Patients:
94 consecutive patients underwent electrophysiological study and ablation for Wolff-Parkinson-White syndrome with left sided accessory connections (81 patients) or ectopic atrial tachycardia (13 patients); 104 transseptal procedures were done; eight patients required multiple procedures.
Results:
92 patients (98%) were initially successfully ablated. Five of 81 with accessory pathways (6%) and three of 13 with atrial tachycardia (23%) required further procedures. One patient with Wolff-Parkinson-White syndrome could not be ablated at a second procedure. Long term success rate for accessory pathway ablation was therefore 99%. Procedures were abandoned in three patients because of minor complications. All were subsequently ablated successfully by a transseptal approach on another day.
Conclusions:
The transseptal approach is safe and effective for ablation of left sided arrhythmias. The technique has similar success rates to the retrograde transaortic approach but without the risk of inadvertent damage to the coronary arteries or aortic valve.
More Related Videos
10:46Non-fluoroscopic Catheter Tracking for Fluoroscopy Reduction in Interventional Electrophysiology
Published on: May 26, 2015
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Cardiac Catheterization I: Pre-Procedure Overview
Cardiac Catheterization III: Left Heart Catheterization
Dysrhythmias VI: Management of Dysrhythmias