Reference Doppler echocardiographic values for St. Jude Medical, Omnicarbon, and Biocor prosthetic valves in the aortic position
Related Experiment Video
Updated: Aug 8, 2026

Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
O Bech-Hanssen1, I Wallentin, S Larsson
1Department of Clinical Physiology, Sahlgrenska University Hospital, Göteborg, Sweden.
Abstract:
The objectives of the present investigation were (1) to describe Doppler echocardiographic findings for mechanical and biologic aortic valves at an early stage after operation and later in a stable phase and (2) to study the changes occurring between these investigations. Patients (n = 213) who received a mechanical (St. Jude Medical, Omnicarbon) or a biologic (Biocor) valve were studied by Doppler echocardiography within the first week (baseline, n = 203) and after 2 years (late, n = 172). The comparison of baseline with late investigation (mean +/- SD) showed an increase in systolic blood pressure (137 +/- 18.5 to 154 +/- 20.6 mm Hg, p = 0.0001, n = 112), reduction of heart rate (85 +/- 15.3 to 74 +/- 12.0 beats/min, p = 0.0001, n = 141) and increase in stroke volume (59 +/- 20.6 to 77 +/- 19.8 ml, p = 0.0001, n = 132). Prosthetic Doppler echocardiographic findings demonstrated a reduction in blood flow velocity in the left ventricular outflow tract (VLVOT, 1.10 +/- 0.25 to 0.96 +/- 0.23 m/sec, p = 0.0001, n = 146) reduction in peak velocity (Vmax 2.72 +/- 0.53 to 2.59 +/- 0.54 m/sec, p = 0.02, n = 150), reduction in mean pressure gradient (deltaPmean, 18.4 +/- 7.2 to 16.3 +/- 7.3 mm Hg, p = 0.004) and an increase in velocity index (Vmax/VLVOT, 2.56 +/- 0.62 to 2.67 +/- 0.60, p = 0.003, n = 144). The standard deviations of difference between baseline and late investigation expressed as percentage of mean were 25% for VLVOT, 20% for Vmax, 44% for deltaPmean, and 25% for velocity index. In conclusion, this large reference base provides data that should be useful for the clinician evaluating patients with prosthetic valves early after valve replacement as well as at a later stage. When valve dysfunction is suspected a previous investigation for comparison is helpful, and our data describe the changes that normally may be seen between an early baseline and a late investigation.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests