Related Experiment Video
Updated: Jun 18, 2026

An Image Guided Transapical Mitral Valve Leaflet Puncture Model of Controlled Volume Overload from Mitral Regurgitation in the Rat
Published on: May 19, 2020
Predictors of systemic embolism in patients with mitral stenosis. A prospective study
1Chang Gung Memorial Hospital and Chang Gung University, Taipei, Taiwan, Republic of China.
Background:
Most studies of the predictors of systemic embolism in patients with mitral stenosis have been retrospective.
Objective:
To prospectively study factors associated with systemic embolism in mitral stenosis.
Design:
Prospective cohort study.
Setting:
University-affiliated medical institution with 3000 beds.
Patients:
534 consecutive patients with a mitral valve area of 2.0 cm2 or less; 132 patients were in sinus rhythm, and 402 were in atrial fibrillation.
Measurements:
Nine clinical and 10 echocardiographic variables were assessed for prediction of systemic embolism over a mean (+/- SD) follow-up of 36.9 +/- 22.5 months. Diagnosis of systemic embolism was based on symptoms and signs (sudden onset of peripheral arterial ischemic or neurologic manifestations without prodromes) and on findings on computed tomography, angiography, and surgery.
Results:
For patients in sinus rhythm, age (relative risk [RR], 1.12 [95% CI, 1.04 to 1.21]), the presence of a left atrial thrombus (RR, 37.1 [CI, 2.82 to 487.8]), mitral valve area (RR, 16.9 [CI, 1.53 to 187.0]), and the presence of significant aortic regurgitation (RR, 22.4 [CI, 2.72 to 184.8]) were positively associated with embolism. For patients in atrial fibrillation, previous embolism (RR, 3.11 [CI, 1.66 to 5.85]) was positively associated with embolism; percutaneous balloon mitral commissurotomy (RR, 0.37 [CI, 0.18 to 0.79]) was a negative predictor.
Conclusions:
It may be prudent to give anticoagulants not only to patients in atrial fibrillation and patients with previous systemic embolism but also to those showing a left atrial thrombus or significant aortic regurgitation on echocardiography. Early percutaneous balloon mitral commissurotomy may also help prevent systemic embolism in patients with mitral stenosis.
Related Concept Videos
Mitral Valve Prolapse II: Assessment and Management
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Mitral Stenosis I: Introduction
Mitral Stenosis II: Clinical features and Diagnostic Tests
Mitral Stenosis III: Medical Management
Mitral Stenosis IV: Nursing Management