A formula to calculate oxygen uptake during low flow anesthesia based on FIO2 measurement
Related Experiment Video
Updated: Oct 29, 2026

Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
1Department of Anesthesiology, University Hospital Zurich, Switzerland. biro@orl.usz.ch
Abstract:
Monitoring of oxygen uptake during general anesthesia would have several benefits, but unfortunately, this is usually not available in the clinical routine situation. The herein proposed formula to calculate oxygen uptake (.VO2) necessitates only the accurate measurement of FIO2 as well as fresh gas flow and composition. Additionally, this method is not affected by the presence of anesthetic gases. The calculation uses the difference in oxygen content between the delivered fresh gas and the resulting FIO2 in the anesthesia circle system. This gap originates from oxygen uptake (that is mainly caused by metabolic oxygen consumption) and is more pronounced if low fresh gas flows are administered. In order to obtain representative results, calculation of .VO2 should be performed only after achievement of respiratory steady state conditions. Due to its simplicity and wide availability, it has the potential to become a valuable extension in anesthesia monitoring during the performance of routine general anesthesia.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
05:46A Novel Inhalation Mask System to Deliver High Concentrations of Nitric Oxide Gas in Spontaneously Breathing Subjects
Published on: May 4, 2021
Related Concept Videos
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...