Highly precise peripheral quantitative computed tomography for the evaluation of bone density, loss of bone density and structures. Consequences for prophylaxis and treatment
Related Experiment Video
Updated: Oct 29, 2026

Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
M A Dambacher1, M Neff, R Kissling
1University Clinic Balgrist, Zurich, Switzerland.
Abstract:
The importance of serial examinations over time with peripheral quantitative computed tomography (pQCT) is that they enable the detection of patients at high risk of osteoporosis, and the individualisation of prophylaxis and treatment. We have shown that postmenopausal patients with high bone turnover evaluated by biochemical markers are identical to fast bone losers as determined by pQCT. As a consequence, we use agents that inhibit bone resorption in patients who are fast bone losers and agents that stimulate bone formation in patients who are slow bone losers. To visualise bone microarchitecture, and to evaluate bone density and the rate of bone loss, we used a highly sensitive pQCT system (DENSISCAN 1000, reproducibility of 0.3% in a mixed population of normal individuals and patients with osteopenia or osteoporosis). This system enabled us to separately assess trabecular and cortical bone density in the radius and tibia, and to differentiate between fast and slow bone losers within a few months (threshold: 3% loss of trabecular bone density in the radius per year). We have shown that the lower the trabecular bone density in the distal radius, the higher the relative bone loss. To classify patients as slow and fast losers in the future, we may need only one measurement. With this highly precise measurement method, we have shown that calcitonin and etidronate are more effective in fast than in slow bone losers, and that vitamin D metabolites (calcitriol or 1 alpha-calcidol) and estrogens can halt fast bone loss. In conclusion, highly sensitive pQCT enables us to adapt the treatment to different forms of osteoporosis and bone turnover, resulting in an increase in the number of patients successfully treated and also in patient compliance. Because our treatment is based on precise, objective measurements, treatment modifications--especially in those who change from a slow to a fast bone-loser state--can be easily justified.
More Related Videos
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
09:36Outer-Boundary Assisted Segmentation and Quantification of Trabecular Bones by an Imagej Plugin
Published on: March 14, 2018
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...