Helical CT of aorta after endoluminal stent-graft therapy: value of biphasic acquisition

J Golzarian1, L Dussaussois, H T Abada

  • 1Department of Radiology, Erasme Hospital, University of Brussels, Belgium.

Insights

Biphasic helical CT effectively detects perigraft leakage after aortic stent-graft placement. This dual-phase imaging improves diagnostic accuracy compared to single-phase CT scans for evaluating endoluminal aortic repair.

Area of Science:

  • Radiology
  • Medical Imaging
  • Cardiovascular Imaging

Background:

  • Endoluminal stent-graft placement is a common treatment for aortic aneurysms.
  • Post-procedure surveillance is crucial to detect complications such as endoleaks.
  • Helical computed tomography (CT) is a primary imaging modality for aortic evaluation.

Purpose of the Study:

  • To prospectively evaluate the diagnostic utility of biphasic helical CT for assessing the aorta after endoluminal stent-graft placement.
  • To compare the effectiveness of biphasic helical CT with single-phase arterial acquisition in detecting perigraft leakage.

Main Methods:

  • A prospective study involving 95 patients with abdominal and thoracic aortic aneurysms who underwent endoluminal stent-graft repair.
  • Biphasic helical CT scans were acquired, including an arterial phase and a delayed phase (15 seconds later).
  • Standardized scanning parameters were used for both phases: 5 mm collimation, 7 mm/rotation table speed, 0.75 sec rotation time, 120 kV, and 295 mA.

Main Results:

  • Perigraft leakage was identified in 45 (47%) of 95 patients.
  • Leakage was detected exclusively on the arterial phase in 8 patients and exclusively on the delayed phase in 3 patients.
  • Biphasic acquisition demonstrated superiority over arterial phase acquisition alone in 15 (16%) of patients for detecting leakage and outflow vessels.

Conclusions:

  • Biphasic helical CT offers superior diagnostic value compared to arterial phase acquisition alone for evaluating the aorta post-endoluminal stent-graft therapy.
  • The dual-phase approach enhances the detection of perigraft endoleaks, improving surveillance accuracy.
  • This technique is valuable for comprehensive assessment of endovascular aortic repair outcomes.