PET instrumentation: what are the limits?

T F Budinger1

  • 1Lawrence Berkeley National Laboratory, Life Sciences Division, Berkeley, CA 94720, USA.

Seminars in Nuclear Medicine
|August 15, 1998
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Real-time quantitative ex vivo direct autoradiography with 10 μm pixel resolution.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2012
Same author

Health effects of in vivo nuclear magnetic resonance.

IEEE engineering in medicine and biology magazine : the quarterly magazine of the Engineering in Medicine & Biology Society·2009
Same author

Multipole shimming of permanent magnets using harmonic corrector rings.

The Review of scientific instruments·2007
Same author

Region-selective effects of neuroinflammation and antioxidant treatment on peripheral benzodiazepine receptors and NMDA receptors in the rat brain.

Journal of neurochemistry·2002
Same author

Imaging transgenic animals.

Annual review of biomedical engineering·2001
Same author

Kinetic analysis of 125I-iodorotenone as a deposited myocardial flow tracer: comparison with 99mTc-sestamibi.

Journal of nuclear medicine : official publication, Society of Nuclear Medicine·2001
Same journal

Letter from the Editors.

Seminars in nuclear medicine·2026
Same journal

Expanding Horizons: The Role of Kaleidoscope and Relevant Images in Seminars in Nuclear Medicine.

Seminars in nuclear medicine·2026
Same journal

The diagnostic performance and clinical value of [18F]FDG PET/CT in pleural mesothelioma - A systematic review and meta-analysis.

Seminars in nuclear medicine·2026
Same journal

Feasibility of treating neuroendocrine prostate cancer with anti-SSTR radioligands: A systematic review of imaging and treatment studies.

Seminars in nuclear medicine·2026
Same journal

<sup>18</sup>F-FDG -PET/CT in cardiac sarcoidosis: Diagnosis, therapy monitoring, and future directions.

Seminars in nuclear medicine·2026
Same journal

Maximizing diagnostic yield: A systematic review and deep dive into PSMA PET scan protocol variations for prostate cancer.

Seminars in nuclear medicine·2026
See all related articles

Positron Emission Tomography (PET) technology has advanced significantly, overcoming historical limitations in detector capabilities and scintillator materials. Future developments aim for 2 mm resolution, enhancing diagnostic imaging across various body regions.

Area of Science:

  • Nuclear medicine and medical imaging technology.
  • Physics of radiation detection and image reconstruction.

Background:

  • Early Positron Emission Tomography (PET) systems faced limitations with count-rate handling and scintillator efficiency, hindering clinical adoption.
  • Advancements in radionuclide applications (e.g., 18F-FDG) and scintillator technology (e.g., LSO) have addressed these historical barriers.

Purpose of the Study:

  • To review the historical development and key attributes of Positron Emission Tomography (PET) technology.
  • To discuss the limitations and factors influencing the current and future development of PET imaging.
  • To highlight advancements in detector technology and their impact on PET performance.

Main Methods:

  • Historical analysis of Positron Emission Tomography (PET) development, focusing on detector technology and performance metrics.

Related Experiment Videos

  • Discussion of key factors: spatial resolution, sensitivity, noise, count-rate capabilities, and radiation dose.
  • Review of advancements in scintillators, detector geometries, and image reconstruction techniques.
  • Main Results:

    • Overcoming historical count-rate limitations with new radionuclides and detector designs.
    • Time-of-flight (TOF) PET potential is being realized with new dense, fast scintillators like LSO.
    • Septaless cylindrical systems have demonstrated significant noise-effective sensitivity improvements, with TOF further enhancing this.

    Conclusions:

    • Future PET detector development focuses on new scintillators, light detection methods, larger fields of view, and compensation for artifacts.
    • The goal is to achieve 2 mm isotropic resolution, with strategies for motion compensation in thorax and abdomen imaging.
    • Continued advancements promise to improve sensitivity and resolution, expanding the clinical utility of PET imaging.