Detection of fetal congenital heart disease in a low-risk population

E Hafner1, J Scholler, K Schuchter

  • 1Ludwig Boltzmann Institute for Clinical Obstetrics and Gynaecology, Department of Obstetrics and Gynaecology, Donauspital am SMZ-Ost, Vienna, Austria.

Prenatal Diagnosis
|September 22, 1998
PubMed

Our purpose was to evaluate the efficacy of level two ultrasound screening for the detection of congenital heart defects (CHD) in a low-risk population by using three standardized cuts. Within a period of four years a total of 6727 pregnant women of a low-risk population undertook several ultrasound examinations on the basis of screening for fetal malformations. All ultrasound examinations were performed by three experienced doctors. At every single scan three standardized cuts (apical and lateral four-chamber view, crossing over of the great arteries) were obtained in order to detect congenital heart defects. Of 87 CHDs (1.33 per cent of the examined women) 39 (43.8 per cent) were diagnosed prenatally. The detection rate was 10/48 (20.8 per cent) in the presence of VSD, ASD2 or combined ASD2 + VSD, the detection rate was 29/39 (74.3 per cent) in the presence of other forms of congenital heart disease. None of the 38 missed cases in the first group but three of the ten missed CHDs in the second group had emergency neonatological problems. Aneuploidy and/or other malformations existed in 22/87 cases of CHD. The obstetrical management was changed in nearly all cases after the diagnosis of a CHD. Twenty-two women opted for termination of pregnancy because of additional fetal malformations or chromosomal defects. Five women were transferred prenatally to a tertiary centre for neonatal cardiac surgery. Ten deliveries were performed in the presence of a neonatologist. Good detection rates for CHD can be achieved in a low-risk population on the basis of level two ultrasound screening by using the above mentioned three cuts and thus, the perinatal mortality and morbidity can be improved.

Related Concept Videos

Fetal Circulation01:14

Fetal Circulation

Fetal circulation is a unique system that facilitates the exchange of gases, nutrients, and waste products between the developing fetus and the mother. This intricate process takes place through a special organ called the placenta.
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...
Imaging Studies for Cardiovascular System III: X-Ray01:20

Imaging Studies for Cardiovascular System III: X-Ray

The most common cardiovascular diagnostic test is an X-ray. It produces images of the heart, blood vessels, and adjacent structures.
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Mitral Stenosis II: Clinical features and Diagnostic Tests01:23

Mitral Stenosis II: Clinical features and Diagnostic Tests

Mitral stenosis is a heart condition in which the mitral valve, which allows blood to flow from the left atrium to the left ventricle, becomes narrowed or stenotic. This narrowing hinders blood flow and leads to clinical symptoms requiring specific medical evaluations and management strategies. The following overview outlines the clinical symptoms, assessments, diagnostic findings, prevention methods, and treatments for mitral stenosis.Clinical ManifestationsDyspnea (shortness of breath): This...