Related Experiment Videos
The sit-to-stand movement in stroke patients and its correlation with falling
P T Cheng1, M Y Liaw, M K Wong
1Department of Physical Medicine and Rehabilitation, Chang Gung Memorial Hospital, Tao-Yuan, Taiwan.
Objective:
To use kinetic assessment of the sit-to-stand movement as a means of sorting out those stroke patients at risk for falling.
Design:
A retrospective study, using a force platform to assess sit-to-stand performance and to determine its correlation with falls in stroke patients.
Setting:
Hospital-based rehabilitation units.
Methods:
Thirty-three stroke patients (18 fallers, 15 nonfallers) and 25 age-matched healthy subjects were included in this study. Subjects sat in an adjustable chair with their feet on two force plates and performed the standing up/sitting down movement at a self-paced, comfortable speed.
Results:
The rate of rise in force (dF/dT) was significantly lower in stroke fallers than in stroke nonfallers and healthy subjects (23.78+/-17.38, 55.23+/-31.24, and 85.96+/-42.4 percent body weight per second, respectively [p < .005]). The center of pressure sway in mediolateral direction during rising/ sitting down was much greater in stroke fallers than in stroke nonfallers or healthy subjects (p < .05). Body weight distribution was asymmetric on the feet of stroke patients, with much more body weight on their sound side.
Conclusions:
The significantly lower rate of rise in force and greater postural sway while rising/sitting down may be useful in identifying stroke patients who are at risk for falling.