Related Experiment Videos
Administration of a crystalloid fluid preload does not prevent the decrease in arterial blood pressure after
R J Turner1, S P Gatt, P C Kam
1Prince of Wales Hospital, Randwick, NSW, Australia.
British Journal of Anaesthesia
|October 15, 1998
Abstract:
Anaesthesia was induced in 58 women (ASA I or II) undergoing elective gynaecological procedures, using propofol 2.5 mg kg-1 and fentanyl 1.5 micrograms kg-1. Patients were allocated to receive 20 ml kg-1 of crystalloid fluid preload over 20 min or to receive no fluids before induction of anaesthesia. A significant decrease in systolic arterial pressure (< 75% of baseline value) occurred in both the fluid-loaded and the control groups, and was similar in both groups. Administration of a fluid preload did not attenuate the decrease in systolic arterial pressure after induction of anaesthesia with propofol and fentanyl.